vfcplmumbai@vimalfire.com +91-22-2578 3335 / 36 / 37 / Toll Free: 1800 890 1999
logo
  • ABOUT US
    • Corporate Film
    • Awards
    • CSR Policy
    • The Most Reliable Fire And Safety Service Providers
  • Applications
  • Products & Solutions
    • Products
    • Industry
    • Approval & Certifications
    • Divisions
    • Alliances
      • Fire Fighting Equipment

      • ● SHOOTFIRE 10500 USGPM UL-Listed Foam Monitor
      • ● SHOOTFIRE 4000 USGPM UL-Listed Foam Monitor
      • ● SHOOTFIRE 2000 USGPM UL-Listed Foam Monitor
      • ● SHOOTFIRE 1000 USGPM UL-Listed Foam Monitor
      • ● SHOOTFIRE Aluminium Alloy Water Monitor
      • ● SHOOTFIRE Aluminium Water Cum Foam Monitor
      • ● Fire Fighting Robot
      • Fire Detection System

      • ● SMARTAUGE Video based Fire Detection System
      • ● LIST - Sensor Based Linear Heat Detection System
      • ● dLIST - Sensor Based Linear Heat Detection System
      • ● ASD-Aspirating Smoke Detection System
      • ● ADW-Line Type Heat Detection System
      • ● Wireless Gas Detection System
      • Fire Supression System

      • ● SHOOTFIRE Gas Based Suppression System (Fixed Clean Agent Gas based Fire Suppression System)
        •  - CO2 Gas
        •  - Novec 1230
        •  - HFC 227ea (FM 200)
      • ● Inergen (IG-541) & Argonite (IG-55)
      • ● ISI & EN Marked SHOOTFIRE Aluminium Body Fire Extinguishers
      • ● ISI & EN Marked SHOOTFIRE MS Body Fire Extinguishers
      • ● Oxygen Reduction Fire Prevention System
      • Specialised Systems

      • ● SHOOTFIRE Rim Seal Fire Protection System
      • ● Video Based Security & Surveillance Solutions
      • ● Crash Fire Tenders
      • ● Smart Modular Consoles
      • ● Fire Detection & Suppression System (FDSS) and Fire Detection & Alarm System (FDAS)
      • ● Unmanned Aerial Vehicle
      • ● Nitrogen Injection Fire Protection System (NIFPS) for Transformers
      • ● Oil & Gas
      • ● Aviation
      • ● Energy
      • ● Mining
      • ● Manufacturing Plants
      • ● Defence
      • ● Railways
      • ● Shipping
      • ● Highway & Transportation
      • ● Pharmaceutical and Chemicals
      • ● Commercial & Consumers Solution
      • ● Power Plants
      • ● IOCL - Rim Seal Fire Protection System Certifications
      • ● HPCL - Rim Seal Fire Protection System Certifications
      • ● BPCL - Rim Seal Fire Protection System Certifications
      • ● IOCL - Foam Monitors Certifications
      • ● HPCL - Foam Monitors Certifications
      • ● BPCL - Foam Monitors Certifications
      • ● ONGC - Rim Seal Fire Protection System Certifications
      • ● ONGC - Foam Monitors Certifications
      • ● Fire Protection System
      • ● Fire Fighting Equipment
      • ● Fire Fighting Vehicles
      • ● Fire Exitnguisihers
      • ● Fire Fighting Chemicals
      • ● Fire Fighting Accessories
      • ● Protective Clothing
      • ● Safety & Rescue Equipment
      • ● Charter Hire / Fire Fighting Services
      • ● Video Based Security & Surveillance Solutions
      • ● Other Vehicles
      • ● Occupational Safety & Health
    •  

  • Downloads
  • Contact Us

Solutions / Products

Home   / Nitrogen Injection Protection System

Nitrogen Injection Protection System

Previous Next
  • About Product
  • For more details

Nitrogen Injection Protection System



Our passion for innovation coupled with profound experience, have helped in developing numerous techno-edge solutions, unique and exclusive solutions in fire safety. One of the key location where fire safety is highly important is the Protection of oil filled Transformers from fire in Power Generation/Transmission/Distribution units. We have developed an ideal Fire Protection Solution using one of the highly sophisticated hollow-metallic tube based Linear Heat Detection System combined with Nitrogen Injection Fire Protection System for internal fire prevention and additional (optional) Water Mist / High Velocity Water Spray / CAF for external fire suppression system. Just the perfect solution for complete Transformer Protection from fire.


SYSTEM DESCRIPTION

A Unique Fire Protection System, which takes care of the health of Transformer and protects it from any unwanted fire internally and (externally). In a Transformer, Internal Fire can occur due to arcing, in core and coil dielectric interruption, ruptures and twist of the winding, improper grounding etc. While external fire erupts due to OLTC, oil leaks, gasket rupture, weld cord, defects of forced cooling fans, Buchholz Relay, exit of the current transformers of the bushings, bursting of bushings, improper / loosening of cable terminations, faults in transmission lines etc.

DETECTION

  • For internal fault Feedback / Trip Signals for activating the signal:

    Differential Trip | IDMT E/F Trip | IDMT O/C Trip | Restricted E/F | WTI Trip | OTI Trip | PRV |Buchholz Relay | Master Trip | Temperature Detector

  • Hollow-Metallic Tube Type Linear Heat Detection System:

    Utmost care is taken in detecting any rise in temperature, Hollow-metallic tube based Linear Heat Detection System can detect fire/heat at incipient stage and generates a command to actuate extinguishing system. Sealed hollow metallic tube filled with ambient air detects rate of rise of Heat Temperature & Maximum Temperature for extremely accurate detection. It evaluates pressure at the rate of 2 samples per second created due to heat. It trips the Transformer when temperature exceeds permissible limit set (customisable / programmable), it can be much below the flash point temperature of oil thus preventing any tank rupture and oil fire in case of arcing generated by internal faults as well as external faults. It avoids any fire or damage to the transformer. The system is site configurable, and the temperature range can be set as per local ambient condition.

    The detection unit is UL, FM & VdS approved.


Basic Principle:
  • Nitrogen Injection Fire Protection System for Internal Fire Prevention:

    Nitrogen Injection Fire Protection System (NIFPS) prevents oil tank explosion or rapture & possible oil fire in event of minor nature of arcing due to internal faults or external faults (such as failure of condenser bushing of transformer or any other source) in Transformer. In case of rise in Temperature inside Transformer due to various reasons, PLC based NIFPS system receives internal inherent Faults / Feedback / Trip Signals from Transformer Panel. In case of any incident PLC based NIFPS system activates electrically operated Transformer Conservator Isolation Valve / Oil Drain Valve / Nitrogen Injection Valve etc. which Isolate the Oil Conservator Tank from main Tank, drains out oil from Transformer into the Oil Pit and Nitrogen gas is injected which creates a layer rest of the oil to avoid any contact with Atmospheric Oxygen.

    Electrically operated steel cage ball valve permits complete opening of oil flow between conservator and main tank thus maintaining original design of OEM. The system also opens the drain valve (Steel Cage Ball Valve) completely, permitting for fastest evacuation of oil from the system. Manual operation is also possible. Our Microprocessor / PLC based System allows Graphical Representation of the faults through SCADA and provides ease of interface with main control panel.

    OPTIONAL FEATURES: Our Unique External Fire Suppression system suppresses, any fire but also cools the system to minimize any further damage;

  • 1. Water Mist Fire Suppression for External Suppression.
  • 2. High Velocity Water Spray System for External Suppression
  • 3. Compressed Air Foam System (CAFS)

for more details


Downloads


Featured Products

  • 10500 US GPM UL-Listed Foam Monitor
  • Aluminium Alloy Water Monitor
  • SMARTAUGE Video based Fire Detection System
  • ISI-Marked Aluminium Body Fire Extinguishers
  • Emergency Robot - G1
  • Hypoxic Air based Fire Prevention System
  • LIST - Sensor Based Linear Heat Detection System
  • dLIST - Sensor Based Linear Heat Detection System

Enquiry Form

Contact Us

Corporate Office

19/20, Vardhman Complex, Behind Punjab & Sind Bank, Opp Home Town, LBS Marg, Vikhroli West, Mumbai - 400083, Maharashtra, India.

Mail Us

vfcplmumbai@vimalfire.com

Call Us

+91-22-2578 3335 / 36 / 37

Toll Free

1800 890 1999

Follow Us

Connect with us

© Copyright 2021 Vimal Fire. All Rights Reserved. Developed by NWDCo

  • INFORMATION CENTRE
  • CLIENTELE
  • CERTIFICATIONS & APPROVALS
  • OUR REGISTERED PARTNERS
  • E-WASTE MANAGEMENT